20% OFF shipping at ktcbardejov.sk on orders over $79 + up to 10% OFF products
ktcbardejov.sk
home > Link TCC08 8 Channel EGT to CAN Module > Link TCC08 8 Channel EGT to CAN Module
download picture
Link TCC08 8 Channel EGT to CAN ModuleLink TCC08 8 Channel EGT to CAN module, powered by CANchecked The TCC08 EGT to CAN module allows you to connect up to eight Type K thermocouples and send the values via CAN bus and or monitor them directly on your wireless enabled device. Type K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before after the intercooler, turbo housings, cylinder head temperatures, water temperature,
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
Link TCC08 8 Channel EGT to CAN module, powered by CANchecked The TCC08 EGT to CAN module allows you to connect up to eight Type-K thermocouples and send the values ​​via CAN bus and/or monitor them directly on your wireless enabled device. Type-K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before/after the intercooler, turbo housings, cylinder head temperatures, water temperature, oil temperature and more. All measurements are cold junction compensated with a measuring range of 0 to 1250°C in 0.25°C resolution (14bit). The TCC08 feature a four-pin DTM connector for CAN & power that is pin compatible with Links standard CAN pinout and CAN cables range. CAN 2.0A/B standard is supported with flexible configuration. Wireless connectivity allows you to configure and update your module via smartphone or PC and query the current temperature and thermocouple status. Features: 8 x cold junction compensated type-K inputs CAN Bus connection to ECU (Pre-Configured for Link ECU) Measuring range from 0 to 1250°C (32 to 2282°F) with 0.25°C resolution Detection of short circuit to ground or if no type-K is connected Standard mini k thermocouple connector Full configuration and monitoring over wireless Adjustable sample frequency up to 100Hz Box Contents: 1 x CAN EGT Module 1 x DTM4 Mating Connector Kit 2 x Link Stickers

Link TCC04 4 Channel EGT to CAN module, powered by CANchecked 


The TCC04 EGT to CAN module allows you to connect up to four Type-K thermocouples and send the values via CAN bus and/or monitor them directly on your wireless enabled device. 


Type-K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before/after the intercooler, turbo housings, cylinder head temperatures, water temperature, oil temperature and more. All measurements are cold junction compensated with a measuring range of 0 to 1250°C in 0.25°C resolution (14bit). 


The TCC04 feature a four-pin DTM connector for CAN & power that is pin compatible with Links standard CAN pinout and CAN cables range. CAN 2.0A/B standard is supported with flexible configuration.  


Wireless connectivity allows you to configure and update your module via smartphone or PC and query the current temperature and thermocouple status. 


Features: 
-    4 x cold junction compensated type-K inputs     
-    CAN Bus connection to ECU (Pre-Configured for Link ECU)     
-    Measuring range from 0 to 1250°C (32 to 2282°F) with 0.25°C resolution     
-    Detection of short circuit to ground or if no type-K is connected     
-    Standard mini k thermocouple connector     
-    Full configuration and monitoring over wireless   
-    Adjustable sample frequency up to 100Hz


Box Contents:  
1 x CAN EGT Module     
1 x DTM4 Mating Connector Kit      
2 x Link Stickers     

 

DTM 4 CAN Pinout (Supports Links CAN pinout schema and CAN cables range)
Pin 1: 12V Pin 2: Ground Pin 3: Can Low Pin 4: Can High
Accuracy: maximum 2% deviation
Dimension (L x W x H) – 97.3 x 31.5 x 34.6mm
 

Configuration Options:

The module can be configured via wireless:

Can Speed: 125kbps, 250kbps, 500kbps, 1Mbps
Emulation: Standard, All major aftermarket EGT/Thermocouple to CAN Modules
Change of standard Can Bus ID
Change Big/Little Endian

Link TCC08 8 Channel EGT to CAN Module

Item no : 65175189317
sold recently : Login >>
US$ 138.00
Pay in 4 interest-free payments of $34.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 138.00

1-11

US$ 124.20

12-35

US$ 96.60

36-59

US$ 82.80

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches